• DocumentCode
    1207966
  • Title

    Estimating coronary artery lumen area with optimization-based contour detection

  • Author

    Luo, Zhongchi ; Wang, Yuanyuan ; Wang, Weiqi

  • Author_Institution
    Dept. of Electron. Eng., Fudan Univ., Shanghai, China
  • Volume
    22
  • Issue
    4
  • fYear
    2003
  • fDate
    4/1/2003 12:00:00 AM
  • Firstpage
    564
  • Lastpage
    566
  • Abstract
    A modified optimization-based contour detection method was presented to compute the lumen area of the coronary artery from intravascular ultrasound (IVUS) video images. First, the search range for the artery inner wall was determined based on the continuity of IVUS video frames. Next, the internal and external energy were calculated to describe the smoothness of the arterial wall and the grayscale variation of ultrasound images, respectively. Here, a novel form of the external energy which combines the gradient and variance of the intensity of image in the radial direction was used. Finally, the minimal energy path based on the optimum contour of the artery wall was obtained using circular dynamic programming (DP). By the comparison with the typical DP procedure using the traditional external energy form, based only on the image gradient, the reliability of this modified method is considerably improved in the measurement of coronary artery lumen area.
  • Keywords
    biomedical ultrasonics; blood vessels; edge detection; medical image processing; video signal processing; IVUS video frame continuity; arterial wall smoothness; artery inner wall; artery wall; circular dynamic programming; coronary artery lumen area; external energy; grayscale variation; image intensity; internal energy; intravascular ultrasound video images; minimal energy path; modified optimization-based contour detection; radial direction; reliability; search range; ultrasound images; Area measurement; Arteries; Diseases; Dynamic programming; Energy measurement; Gray-scale; Medical treatment; Optimization methods; Ultrasonic imaging; Ultrasonic variables measurement; Algorithms; Anatomy, Cross-Sectional; Arteries; Coronary Vessels; Feasibility Studies; Humans; Image Interpretation, Computer-Assisted; Pattern Recognition, Automated; Quality Control; Ultrasonography, Interventional;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2003.811048
  • Filename
    1200937