DocumentCode
1208784
Title
Longitudinal Mixing in a Cast of the Human Larynx
Author
Simone, Arthur F.
Author_Institution
Bioengineering Program, Pennsylvania State University
Issue
7
fYear
1981
fDate
7/1/1981 12:00:00 AM
Firstpage
493
Lastpage
495
Abstract
A cast of a human larynx was constructed and used to measure dispersion of a pulse of oxygen tracer in an inspiratory flow of 21.8 1/min. Maximum time-averaged and fluctuating velocities were measured at points downstream of the cast and were used to explain tracer dispersion in terms of the velocity profiles and turbulence at each position.
Keywords
Diseases; Dispersion; Fasteners; Fluid flow measurement; Humans; Impulse testing; Larynx; Position measurement; Pulse measurements; Velocity measurement; Adult; Biophysics; Humans; Inhalation; Larynx; Models, Biological; Oxygen; Respiratory Function Tests;