DocumentCode :
1209733
Title :
Space Scintillator-Detector Distinguishing between Protons and Electrons
Author :
Bloom, S.D. ; Kaifer, R.C. ; Schrader, C.D.
Author_Institution :
Lawrence Rad. Lab., University of California, Livermore, Calif.
Volume :
7
Issue :
42403
fYear :
1960
fDate :
6/1/1960 12:00:00 AM
Firstpage :
170
Lastpage :
174
Abstract :
A space scintillator detector has been designed and tested which meets the following requirements: 1) detection and separation of protons with energy greater than 1.5 mev and electrons with energy greater than 50 kev; 2) power consumption of less than 350 milliwats; and 3) weight less than 5 pounds. The basic detector consists of a stilbene scintillator on an RCA 6199 photomultiplier (or the C7151C ruggedized model). The electron-proton separation is accomplished through a circuit which makes use of the different light decay times caused by electrons and protons in the scintillator. The entire package including the amplifiers, scalers, and high voltage supply occupies a space 5 inches in diameter by 10 inches long. The unit has been tested for thermal stability and vibrational shock. A second detector, not restricted to the above power and weight requirements, is being developed to obtain pulse height information as well.
Keywords :
Circuits; Detectors; Electrons; Energy consumption; Packaging; Photomultipliers; Protons; Pulse amplifiers; Testing; Voltage;