Title :
Undesired Background Subtraction in a Logarithmic Count Rate Meter Circuit
Author :
DeBolt, Harold E.
Author_Institution :
AVCO Research and Advanced Development Division Wilmington, Massachusetts
fDate :
4/1/1961 12:00:00 AM
Abstract :
Background compensation can be accomplished by simple subtraction of a background signal in the linear count rate meter. However, in the logarithmic count rate meter circuit (Cooke-Yarborough type), compensation must be accomplished by subtraction from each section of the logarithmic circuit before summing the outputs of the sections. The method is described and mathematically justified in the following article.
Keywords :
Chromium; Filters; Instruments; Pulse circuits; Radiation detector circuits; Radiation detectors; Radiation monitoring; Rectifiers; Smoothing methods; Voltage;
Journal_Title :
Nuclear Science, IRE Transactions on
DOI :
10.1109/TNS2.1961.4315822