DocumentCode :
1210453
Title :
Reactor Power Monitor Utilizing Cerenkov Radiation
Author :
Lovvorn, James L.
Author_Institution :
Instrumentation and Controls Division Oak Ridge National Laboratory Oak Ridge, Tennessee
Volume :
8
Issue :
4
fYear :
1961
Firstpage :
3
Lastpage :
5
Abstract :
Cerenkov light in the central region of a water-moderated reactor has been measured as a function of reactor power. Simple photovoltaic light detectors were used with a recording microammeter. The electrical current responded to a power increment increase with an initial rise proportional to the reactor power. This was followed by an additional increase in current of from 4 to 5% with a time constant of approximately 4 minutes.
Keywords :
Delay; Detectors; Gamma rays; Inductors; Instruments; Leak detection; Lighting control; Neutrons; Power measurement; Radiation monitoring;
fLanguage :
English
Journal_Title :
Nuclear Science, IRE Transactions on
Publisher :
ieee
ISSN :
0096-2015
Type :
jour
DOI :
10.1109/TNS2.1961.4315849
Filename :
4315849
Link To Document :
بازگشت