DocumentCode
1211380
Title
Limits of Resolution in Magnetically Focused Image Converter Tubes
Author
Papp, G.
Author_Institution
ITT Federal Laboratories Fort Wayne, Indiana
Volume
9
Issue
2
fYear
1962
fDate
4/1/1962 12:00:00 AM
Firstpage
91
Lastpage
93
Abstract
In a simple image tube in which the uniformly accelerated electrons are focused by a homogeneous magnetic field onto the phosphor, the error in focusing due to the aribtrary initial velocity of the photoelectrons is calculated. It is shown that optimm resolution can be obtained if focusing is adjusted for electrons leaving the cathode at the average initial forward velocity. A method to measure the initial average transverse velocity in the tube itself is developed. A practical formula for the expected resolution is derived (see Equation 12) for tubes with S-11 photocathodes and for the incident light coming from a slightly underheated incandescent lamp.
Keywords
Acceleration; Anodes; Cathodes; Electrons; Focusing; Image converters; Laboratories; Magnetic field measurement; Magnetic fields; Phosphors;
fLanguage
English
Journal_Title
Nuclear Science, IRE Transactions on
Publisher
ieee
ISSN
0096-2015
Type
jour
DOI
10.1109/TNS2.1962.4315956
Filename
4315956
Link To Document