• DocumentCode
    1211828
  • Title

    Reduction of Delay between Particle Passage and Spark Chamber Spark

  • Author

    Fischer, Joachim ; Zorn, Gus T.

  • Author_Institution
    Brookhaven National Laboratory Upton, N. Y.
  • Volume
    9
  • Issue
    3
  • fYear
    1962
  • fDate
    6/1/1962 12:00:00 AM
  • Firstpage
    261
  • Lastpage
    274
  • Abstract
    The delay time between the passage of an ionizing particle and the spark-chamber spark is one of the limiting factors in the time resolution of spark-chamber systems. The usual resolving time is of the order of 0.5 ¿sec. The delay time in photomultipliers, cables, coincidence mixers, high voltage pulse generators, spark gaps, spark chamber voltage rise, and spark formation is investigated. Elements of a system are described which result in a total delay of about 33 nsec, including the photomultiplier. This may permit a reduction in spark chamber memory time and time resolution by about one order of magnitude. The reduction in delays and rise times also decreases the displacement of tracks in spark chambers operating in a magnetic field.
  • Keywords
    Cables; Counting circuits; Delay effects; Delay systems; Magnetic fields; Particle beams; Particle tracking; Photomultipliers; Spark gaps; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IRE Transactions on
  • Publisher
    ieee
  • ISSN
    0096-2015
  • Type

    jour

  • DOI
    10.1109/TNS2.1962.4316006
  • Filename