DocumentCode
1212272
Title
Redundant Pulse Amplifier
Author
Somer, Toivo A.
Author_Institution
Research Laboratories Division the Bendix Corporation Southfield (Detroit), Michigan
Volume
9
Issue
5
fYear
1962
Firstpage
7
Lastpage
16
Abstract
A redundant transistorized pulse amplifier is described, composed of a remote preamplifier operating at -80°C and a main pulse amplifier. Active parallel redundancy is used in the preamplifier as well as in the main amplifier. Common feedback between the parallel redundant amplifiers stabilizes the voltage amplification in spite of component failures in one signal path. Delay-line pulse shaping is employed to reduce noise and to eliminate the detrimental effects of pulse pile-up.
Keywords
Capacitance; Circuits; Laboratories; Operational amplifiers; Photomultipliers; Preamplifiers; Pulse amplifiers; Pulse shaping methods; Redundancy; Satellites;
fLanguage
English
Journal_Title
Nuclear Science, IRE Transactions on
Publisher
ieee
ISSN
0096-2015
Type
jour
DOI
10.1109/TNS2.1962.4316058
Filename
4316058
Link To Document