• DocumentCode
    1215802
  • Title

    Fast shutter for low background radiation environments at SPR III

  • Author

    Kelly, John G. ; Sites, Kenneth R. ; Scott, William H.

  • Author_Institution
    Sandia Nat. Labs., Albuquerque, NM, USA
  • Volume
    41
  • Issue
    6
  • fYear
    1994
  • Firstpage
    2125
  • Lastpage
    2131
  • Abstract
    A fast shutter system has been developed to isolate experiments from the radiation emitted after the main pulse of the Sandia Pulsed Reactor, SPR III. In about 15 ms the system moves a 20 kg shield in front of the beam port aperture in the facility shield wall. A second gravity-driven shutter is dropped into place in about 200 ms. The total attenuation achieved in the delayed beam intensity is about a factor of one hundred. The shutter assembly was used, along with a sensitive detection system, to observe the gamma ray flux emitted by various materials activated by the neutron beam at levels nine orders of magnitude smaller than the gamma dose rate at the target during the reactor pulse.<>
  • Keywords
    dosimetry; fission research reactors; gamma-ray detection; neutron activation analysis; neutron flux; radiation protection; safety systems; shielding; SPR III; Sandia Pulsed Reactor; attenuation; fast shutter system; gamma ray flux; gravity-driven shutter; low background radiation environments; materials; shield; Apertures; Attenuation; Delay; Inductors; Laboratories; Neutrons; Pulse measurements; Radiation monitoring; Scattering; System testing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.340552
  • Filename
    340552