Abstract
Epoch-based electromyogram (EMG) amplitude estimates have not incorporated signal whitening, even though whitening has demonstrated significant improvements for stream-based estimates. This work presents new epoch-based algorithms, for both single- and multiple-channel EMG, which include a whitening stage. The best multiple-channel whitening processor provided a 21.4%-22.5% improvement over single-channel unwhitened estimation in an EMG-to-torque application.
Keywords
Wiener filters; adaptive filters; electromyography; estimation theory; medical signal processing; adaptive signal whitening; electromyogram amplitude estimation; epoch-based applications; multiple-channel whitening processor; Adaptive filters; Additive noise; Amplitude estimation; Biomedical computing; Biomedical engineering; Biomedical measurements; Biomedical signal processing; Electromyography; Motion control; Signal processing algorithms; Biomedical signal processing; EMG amplitude estimation; electromyography; functional electrical stimulation; myoelectric signal processing; whitening; Algorithms; Computer Simulation; Diagnosis, Computer-Assisted; Electromyography; Humans; Models, Biological; Models, Statistical; Muscle Contraction; Muscle, Skeletal; Signal Processing, Computer-Assisted;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/TBME.2004.840498
Filename
1386571
Link To Document