DocumentCode
1217553
Title
Considerations Affecting the Mitigation of Noise Coupled Between Cable Pairs
Author
Ward, Henry C.
Author_Institution
New Jersey Bell Telephone Co., Newark, NJ
Volume
15
Issue
4
fYear
1967
fDate
8/1/1967 12:00:00 AM
Firstpage
648
Lastpage
652
Abstract
Certain mitigative measures which can be employed against metallic noise coupled into telephone circuits in the outside plant are discussed. Quantitative restults are given for separate entrance cable, flat gain amplifiers, arid noise suppression coils. The model used appears to be well-suited to the typical impulse noise problem.
Keywords
Amplifiers; Audio frequency; Crosstalk; Outside plant; Repeaters; Subscriber loops; Telephone equipment; Telephone systems; Transmission; signal-to-noise ratio (SNR); Circuit noise; Communication cables; Communications technology; Conductors; Crosstalk; Noise level; Noise measurement; Repeaters; Signal to noise ratio; Telephony;
fLanguage
English
Journal_Title
Communication Technology, IEEE Transactions on
Publisher
ieee
ISSN
0018-9332
Type
jour
DOI
10.1109/TCOM.1967.1089621
Filename
1089621
Link To Document