DocumentCode :
1217777
Title :
An Investigation of Lithium Ion Sources on an Applied-B Extraction Diode on a PI-110A Accelerator
Author :
McKay, P.F. ; Gerber, R.A. ; Pregenzer, A.L.
Volume :
15
Issue :
4
fYear :
1987
Firstpage :
339
Lastpage :
345
Abstract :
As part of the effort to develop an electrohydrodynamically (EHD) driven lithium ion source for the Particle Beam Fusion Accelerator II (PBFA II) at Sandia National Laboratories, we have begun experiments with liquid lithium and liquid lithium nitrate-filled anodes on the PI-110A accelerator. Several methods have been used to provide a lithium or lithium-bearing vertical anode surface that can be maintained above its melting point. Here we report preliminary results which indicate that a high purity (> 80 percent) Li+ beam is achievable from these anodes. Diagnostics include measurements of diode voltage, diode current, ion current, and a Thomson parabola analyzer to measure ion species. The possibility that ions are produced by an EHD phenomenon is discussed. Other mechanisms of ion production are considered.
Keywords :
Acceleration; Anodes; Current measurement; Diodes; Ion accelerators; Ion sources; Laboratories; Lithium; Particle accelerators; Particle beams;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/TPS.1987.4316717
Filename :
4316717
Link To Document :
بازگشت