DocumentCode :
1218980
Title :
Built-in sensor based on current supply high-frequency behaviour
Author :
Lechuga, Y. ; Mozuelos, R. ; Martinez, M. ; Bracho, S.
Author_Institution :
Dept. of Electron. Technol., Univ. of Cantabria, Santander, Spain
Volume :
39
Issue :
10
fYear :
2003
fDate :
5/15/2003 12:00:00 AM
Firstpage :
775
Lastpage :
777
Abstract :
A built-in sensor based on the detection of highest frequency components of the dynamic current supply of the circuit under test is proposed. In analogue SI circuits, there are faults difficult to detect using conventional test methods. It is possible to detect these faults by the changes in the slope of the dynamic current supply.
Keywords :
built-in self test; circuit testing; electric current measurement; electric sensing devices; fault diagnosis; switched current circuits; analogue switched-current circuit testing; built-in sensor; fault detection; high-frequency dynamic current supply;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:20030475