DocumentCode
1219043
Title
Some Aspects of Nonstationary Myoelectric Signal Processing
Author
Xiong, Fuqin Q. ; Shwedyk, Ed
Issue
2
fYear
1987
Firstpage
166
Lastpage
172
Abstract
Nonstationary myoelectric signal processing is considered. A midpoint moving average estimator for the signal variance is developed. The performance of the estimator is analyzed and optimum window size criteria are derived. Comparison of the theoretical performance to experimental performance shows good agreement. The resultant estimation error is only moderately (2-3 percent) degraded from the equivalent stationary case. Finally, the developed estimator is compared to a typical squarer followed by a low-pass filter myoelectric processor. Provided that the low-pass filter has a linear phase characteristic in the passband, the two systems have essentially the same error performance.
Keywords
Degradation; Electromyography; Estimation error; Low pass filters; Maximum likelihood estimation; Muscles; Nonlinear filters; Passband; Performance analysis; Signal processing; Electromyography; Humans; Mathematics; Signal Processing, Computer-Assisted;