• DocumentCode
    1219371
  • Title

    A Non-Contact Micro-Displacement Meter

  • Author

    Sharaf, Harold

  • Author_Institution
    Laboratory for Electronics, Inc. Boston, Massachusetts
  • fYear
    1954
  • fDate
    6/1/1954 12:00:00 AM
  • Firstpage
    14
  • Lastpage
    25
  • Abstract
    A method capable of detecting microinch displacements of a transducer surface vibrating in the fractional megacycle range has been developed. The dynamic displacements of a vibrating transducer are detected with the aid of a specialized frequency modulation system. The vibrating transducer face is incorporated into the system in a manner such that the center frequency of an oscillator is varied in accordance with the transducer vibrations. The frequency modulation system transforms the frequency, deviations into a corresponding amplitude varying signal. In this way, accurate measurements of transducer vibrations can readily be obtained. The system is inherently capable of detecting transducer displacements with equal facility in either air or a viscous fluid.
  • Keywords
    Capacitance; Frequency measurement; Frequency modulation; Oscillators; Probes; Transducers;
  • fLanguage
    English
  • Journal_Title
    Ultrasonic Engineering, Transactions of the IRE Professional Group on
  • Publisher
    ieee
  • ISSN
    0277-626X
  • Type

    jour

  • DOI
    10.1109/TPGUE.1954.1538193
  • Filename
    1538193