• DocumentCode
    1219730
  • Title

    Superconducting Magnets and Cooling System in BEPCII

  • Author

    Wang, L. ; Xu, F.Y. ; Liu, X.K. ; Yang, G.D. ; Cui, J.S. ; Ji, Z.M. ; Bai, W. ; Jia, L.X.

  • Author_Institution
    Harbin Inst. of Technol., Harbin
  • Volume
    18
  • Issue
    2
  • fYear
    2008
  • fDate
    6/1/2008 12:00:00 AM
  • Firstpage
    146
  • Lastpage
    149
  • Abstract
    A pair of dual-purpose superconducting quadrupole magnets and a superconducting detector solenoid were fabricated and installed in Beijing Electron-Positron Collider Upgrade (BEPCII). The magnets are symmetrically inserted into the BESIII detector with respect to the interaction point. They are identical, iron-free, non-collared, multi-layered and active shielded superconducting magnets for the micro-beta focusing at the interaction region of the collider rings. Each quadrupole magnet is composed of seven coils at different operating currents wound layer by layer on a common cylindrical support. The magnet has an overall effective length of 0.96 m and provides a good field aperture of 65 mm in diameter. They are cooled by supercritical helium in order to eliminate the flow instabilities in constrained cooling channels. The BESIII superconducting solenoid magnet was designed to provide an axial magnetic field of about 1.0 T over the tracking volume and to meet the requirement of particle momentum resolution to particle detectors. A single layer of coil, in-direct cooling by forced two-phase helium, high purity aluminum based stabilizer and NbTi/Cu superconductor is adopted for the solenoid. The solenoid is 3.4 m in diameter and 3.89 m in length. This paper presents the design of the superconducting magnets in the BEPCII as well as their cryomodules. The cooling system for the magnets is also discussed.
  • Keywords
    accelerator magnets; colliding beam accelerators; copper; electron accelerators; electron beam focusing; niobium alloys; superconducting coils; superconducting magnets; superconducting particle detectors; titanium alloys; BEPCII; Beijing Electron-Positron Collider Upgrade; NbTi-Cu; coils; cryomodules; forced two-phase helium; high purity aluminum based stabilizer; in-direct cooling system; microbeta focusing; particle momentum resolution; size 3.4 m; size 3.89 m; size 65 mm; superconducting detector solenoid fabrication; superconducting quadrupole magnets design; supercritical helium; Accelerators; cooling; particle detectors; superconducting magnet;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/TASC.2008.922283
  • Filename
    4520406