  • Abstract
    An uncomplicated circuit to sample a signal and digitally store its value is given. A modification to store the maximum or minimum value attained by the signal is also presented. The drift for these circuits is small, and the input signal may be obtained in digital form.
  • Keywords
    Analog circuits; Automatic control; Biomedical monitoring; Delay effects; Digital circuits; ISO standards; Standards organizations; Switching circuits; Switching converters; Voltage; Automatic Data Processing; Physiology;