Title :
The Single Langmuir Probe under Orbital-Limited Conditions in a Low-Density Collisional Plasma
Author :
Dwarakanath, K. ; Rau, R.S.N.
fDate :
3/1/1979 12:00:00 AM
Abstract :
The cylindrical Langmuir probe under orbital-limited conditions was used to determine the charge density in a low-density collisional plasma. The Langmuir´s theory was applied to both electron and ion saturation currents in their respective accelerating regions. Present study indicates that the length of the probe significantly affects the probe characteristics. A probe of suitable length under orbital-limited conditions may be useful under the experimental conditions where the radius of the probe is much smaller than the Debye lengt.
Keywords :
Argon; Electrons; Extraterrestrial measurements; Fault location; Plasma accelerators; Plasma density; Plasma measurements; Plasma properties; Plasma sources; Probes;
Journal_Title :
Plasma Science, IEEE Transactions on
DOI :