DocumentCode
1221701
Title
Practical Considerations in the Implementation of the French-Holden Algorithm for Sampling of Neuronal Spike Trains
Author
Paterka, R.J. ; Sanderson, A.C. ; O´leary, D.P.
Author_Institution
Biomedical Engineering Program, Carnegie-Mellon University, Pittsburgh, PA and the Department of Otolaryngology, Eye and Ear Hospital, University of Pittsburgh
Issue
2
fYear
1978
fDate
3/1/1978 12:00:00 AM
Firstpage
192
Lastpage
195
Abstract
The French-Holden algorithm (1), (2), (3) provides a sampled data time series representation of a neuronal spike train in order to facilitate subsequent analyses by conventional signal processing techniques. Two characteristics of this filtering algorithm make the choice of data record length particularly important: (a) an ideal, sharp cutoff filter is used on the spike train, and (b) the Nyquist sampling frequency is chosen exactly equal to the filter cutoff frequency. In this note, sources of distortion and aliasing errors due to finite data records are discussed and guidelines for the selection of minimum record length are given.
Keywords
Algorithm design and analysis; Cutoff frequency; Filtering algorithms; Filters; Guidelines; Sampling methods; Signal analysis; Signal processing algorithms; Signal sampling; Time series analysis; Action Potentials; Mathematics;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/TBME.1978.326246
Filename
4122803
Link To Document