• DocumentCode
    1222564
  • Title

    Testing of a 100-kV 100-Hz Rep-Rate Gas Switch

  • Author

    Ramrus, A. ; Shannon, J.

  • Volume
    8
  • Issue
    3
  • fYear
    1980
  • Firstpage
    160
  • Lastpage
    162
  • Abstract
    A two-electrode gas switch with a self-breakdown voltage of 100 kV was operated at a pulse-repetition rate (PRR) of 100 Hz with bursts up to 10 s in duration. The output of a pulse transformer provided the (1 - cos ¿t) waveform which charged the switch in about one-half ms. The switch discharged with a peak current of about 10 kA and a total charge transfer of about 10 mC into a damped LC circuit. A continuous purge of air through the interelectrode spacing enabled the switch to recover its breakdown voltage between discharges. Flow rates up to 35 standard cubic feet per minute (scfm) were employed. This paper discusses the dependence of switch jitter and waveform reproducibility on airflow rate.
  • Keywords
    Charge transfer; Circuit testing; Diodes; Jitter; Pulse generation; Pulse transformers; Spark gaps; Switches; Switching circuits; Thyratrons;