DocumentCode :
1222745
Title :
Two dimensional tracking with surface barrier silicon detectors
Author :
Apollinari, G. ; Belforte, S. ; Focardi, E. ; Paoletti, R. ; Tonelli, G. ; Zetti, F.
Author_Institution :
INFN, Pisa, Italy
Volume :
36
Issue :
1
fYear :
1989
fDate :
2/1/1989 12:00:00 AM
Firstpage :
46
Lastpage :
53
Abstract :
The authors describe the performance of surface barrier silicon detectors with x,y readout electrodes which have been fabricated and tested with minimum ionizing particles. The impact points of the incoming particles are reconstructed with an accuracy of 52 μm and 300 μm, respectively, for the two coordinates, and each detector provides a fully two-dimensional plot of the beam profile. Global efficiency, edge effects, and two-particle resolution in both coordinates are reported. It is concluded that the strong correlation between the charges collected on the two sides is helpful in solving ambiguities in about 80% of the events with two particles
Keywords :
position sensitive particle detectors; semiconductor counters; Si; beam profile; edge effects; efficiency; surface barrier silicon detectors; two-dimensional; two-particle resolution; Diodes; Electrodes; Energy resolution; Face detection; Particle beams; Position sensitive particle detectors; Preamplifiers; Silicon; Strips; Testing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.34399
Filename :
34399
Link To Document :