DocumentCode :
1222750
Title :
Response of a Wall-Stabilized Air Arc to Step and Sinusoidal Change in Current
Author :
Matsumura, T. ; Sakakibara, T. ; Kito, Y. ; Miyachi, I.
Volume :
8
Issue :
3
fYear :
1980
Firstpage :
248
Lastpage :
252
Abstract :
Numerical calculations are performed with respect to transient characteristics of a 5-mm-diam wall-stabilized air arc at atmospheric pressure. The mass and energy equations are solved by means of a computer into which all the numerical data of the transport properties are memorized against gas temperature. The transient responses of temperature profile, arc conductance, and electric field strength to step and sinusoidal change in current are estimated. It is found that an arc time constant is given as a function of the axial temperature of arc column. The experimental results show good agreement with the calculated ones.
Keywords :
Conductors; Equations; Fluid flow; Gases; Insulation; Plasma temperature; Power system transients; Temperature dependence; Temperature distribution; Thermal conductivity;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/TPS.1980.4317313
Filename :
4317313
Link To Document :
بازگشت