• DocumentCode
    1222750
  • Title

    Response of a Wall-Stabilized Air Arc to Step and Sinusoidal Change in Current

  • Author

    Matsumura, T. ; Sakakibara, T. ; Kito, Y. ; Miyachi, I.

  • Volume
    8
  • Issue
    3
  • fYear
    1980
  • Firstpage
    248
  • Lastpage
    252
  • Abstract
    Numerical calculations are performed with respect to transient characteristics of a 5-mm-diam wall-stabilized air arc at atmospheric pressure. The mass and energy equations are solved by means of a computer into which all the numerical data of the transport properties are memorized against gas temperature. The transient responses of temperature profile, arc conductance, and electric field strength to step and sinusoidal change in current are estimated. It is found that an arc time constant is given as a function of the axial temperature of arc column. The experimental results show good agreement with the calculated ones.
  • Keywords
    Conductors; Equations; Fluid flow; Gases; Insulation; Plasma temperature; Power system transients; Temperature dependence; Temperature distribution; Thermal conductivity;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/TPS.1980.4317313
  • Filename
    4317313