• DocumentCode
    1222778
  • Title

    The Operating Region of MHD Generators

  • Author

    Trung, D.T. ; Messerle, H.K.

  • Volume
    8
  • Issue
    3
  • fYear
    1980
  • Firstpage
    269
  • Lastpage
    275
  • Abstract
    The concept of an overall operating region for segmented Faraday magnetohydrodynamic (MHD) generators is established. The resulting diagram indicating optimal operating conditions relates generator mass flow rate to inlet stagnation pressure. It provides information on the generator inlet Mach number, the electrical load factor, the total electrical power output, and the percentage enthalpy extraction (PEE) for any possible operating condition of a specifilc generator. The diagram is a useful tool in specifying the behavior of the generator under changing operational conditions and for anticipating the formation of shock fronts inside the generator channel, an occurrence which is very undesirable from an electrical engineering point of view. Conclusions drawn indicate that the optimal operating range for maximum electrical power output lies on the boundary between the transonic and supersonic flow regimes at relatively low inlet stagnation pressures. The maximum PEE occurs at a somewhat lower power with the electrical loading factor K ¿ 0.5.
  • Keywords
    Circuits; Data mining; Electric shock; Electrical engineering; Electrodes; Magnetohydrodynamic power generation; Plasma temperature; Power generation; Switches; Voltage;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/TPS.1980.4317316
  • Filename