• DocumentCode
    1222857
  • Title

    Fast tracking detector with fiber scintillators and a position sensitive photomultiplier

  • Author

    Salomon, M. ; Li, V. ; Smith, G. ; Wu, Y.S.

  • Author_Institution
    TRIUMF, Vancouver, BC, Canada
  • Volume
    36
  • Issue
    1
  • fYear
    1989
  • fDate
    2/1/1989 12:00:00 AM
  • Firstpage
    94
  • Lastpage
    97
  • Abstract
    The properties of tracking detector composed of 32 fiber scintillators coupled to a multianode photomultiplier placed in a pion beam at TRIUMF were studied. The efficiency of the detector was measured as well as its tracking capabilities and double-hit resolution. It is concluded that the combination of fiber scintillators coupled to a position-sensitive photomultiplier can operate as a fast tracking detector with almost 100% efficiency at rates up to the MHz region and can easily recognise single-and double-hit events with correct fiber identification. It can do this with algorithms simple enough to be used for online identification
  • Keywords
    photomultipliers; position sensitive particle detectors; scintillation counters; MHz region; TRIUMF; double-hit resolution; fiber scintillators; multianode photomultiplier; pion beam; position sensitive photomultiplier; tracking capabilities; tracking detector; Petroleum; Photomultipliers; Position sensitive particle detectors; Table lookup;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.34409
  • Filename
    34409