Abstract
The properties of tracking detector composed of 32 fiber scintillators coupled to a multianode photomultiplier placed in a pion beam at TRIUMF were studied. The efficiency of the detector was measured as well as its tracking capabilities and double-hit resolution. It is concluded that the combination of fiber scintillators coupled to a position-sensitive photomultiplier can operate as a fast tracking detector with almost 100% efficiency at rates up to the MHz region and can easily recognise single-and double-hit events with correct fiber identification. It can do this with algorithms simple enough to be used for online identification
Keywords
photomultipliers; position sensitive particle detectors; scintillation counters; MHz region; TRIUMF; double-hit resolution; fiber scintillators; multianode photomultiplier; pion beam; position sensitive photomultiplier; tracking capabilities; tracking detector; Petroleum; Photomultipliers; Position sensitive particle detectors; Table lookup;