• DocumentCode
    1223244
  • Title

    Charge correlation measurements from a double-sided solid state ministripe detector

  • Author

    Kalbfleisch, G.R. ; Skubic, P.L. ; Lambrecht, M.A. ; Wilburn, C.D.

  • Author_Institution
    Oklahoma Univ., Norman, OK, USA
  • Volume
    36
  • Issue
    1
  • fYear
    1989
  • fDate
    2/1/1989 12:00:00 AM
  • Firstpage
    272
  • Lastpage
    275
  • Abstract
    Good signal correlations were obtained between orthogonal stripes on opposite sides of two double-sided silicon ministripe detectors. The devices were 40 mm×40 mm×300-μm thick, with 40 stripes on each side. Interstripe resistances were measured under unbiased and overbiased conditions. The noise of each channel was measured as a function of bias voltage. The results indicate that the detectors work well as position-sensitive detectors
  • Keywords
    charge measurement; electric resistance measurement; electron device noise; position sensitive particle detectors; semiconductor counters; 300 mum; 40 mm; charge correlations; double sided Si ministripe detector; interstripe resistances; noise; position-sensitive detectors; signal correlations; Charge measurement; Current measurement; Gas detectors; Microstrip; Noise measurement; Probability distribution; Semiconductor device noise; Signal to noise ratio; Silicon devices; Solid state circuits;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.34448
  • Filename