Title :
A cryogenic monitor system for the liquid argon calorimeter in the SLD detector
Author :
Fox, Michael J. ; Fox, John D.
Author_Institution :
Linear Accel. Center, Stanford Univ., CA, USA
fDate :
2/1/1989 12:00:00 AM
Abstract :
The authors describe the monitoring electronics system design for the liquid argon calorimeter (LAC) portion of the SLD (Stanford Linear Collider Large Detector). This system measures temperatures and liquid levels inside the LAC cryostat and transfers the results over a fiber-optic serial link to an external monitoring computer. System requirements, unique design constraints, and detailed analog, digital, and software designs are presented. Fault tolerance and the requirement for a single design to work in several different operating environments are discussed
Keywords :
analogue circuits; calorimeters; computerised monitoring; cryogenics; digital integrated circuits; SLD detector; analog design; cryogenic monitor system; design; digital design; fault tolerance; liquid Ar calorimeter; monitoring electronics; software designs; Argon; Computerized monitoring; Cryogenics; Detectors; Instruments; Light emitting diodes; Los Angeles Council; Optical fiber communication; Superluminescent diodes; Temperature measurement;
Journal_Title :
Nuclear Science, IEEE Transactions on