• DocumentCode
    1224549
  • Title

    An AC bridge readout for bolometric detectors

  • Author

    Rieke, F.M. ; Lange, A.E. ; Beeman, J.W. ; Haller, E.E.

  • Author_Institution
    Dept. of Phys., California Univ., Berkeley, CA, USA
  • Volume
    36
  • Issue
    1
  • fYear
    1989
  • fDate
    2/1/1989 12:00:00 AM
  • Firstpage
    946
  • Lastpage
    949
  • Abstract
    The authors have developed a bolometer readout circuit which greatly improves the low-frequency stability of bolometric detectors. The circuit uses an AC bias voltage and two matched bolometers and allows stable DC bolometer operation for integration times ⩾10 s. In astronomical applications the readout allows for qualitatively different observation modes (e.g. staring or slow-drift scanning) which are particularly well suited for space observations and for the use of arrays. In many applications the readout can increase sensitivity. The authors present noise spectra for 4He temperature bolometers with no excess noise at frequencies greater than 0.1 Hz. The measured optical responsivity of a bolometer operated with the present readout is the same as that of a bolometer operated with a conventional readout
  • Keywords
    bolometers; bridge circuits; AC bridge readout; astronomical applications; bolometric detectors; low-frequency stability; noise spectra; stable DC bolometer operation; Bolometers; Bridge circuits; Circuit stability; Detectors; Extraterrestrial measurements; Frequency; Helium; Optical noise; Temperature sensors; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.34581
  • Filename
    34581