DocumentCode
1225355
Title
Author´s Response
Author
Kong-Pang Pun ; Chatterjee, Saptarshi ; Kinget, Peter
Author_Institution
Chinese Univ. of Hong Kong, Hong Kong
Volume
42
Issue
10
fYear
2007
Firstpage
2315
Lastpage
2315
Abstract
In the above paper [1], a mistake in the schematic diagram of the 0.5-V operational transconductance amplifier (OTA) (Fig. 11) was discovered by Prof. Dr. Martin Schubert of FH Regensburg, University of Applied Sciences, Regensburg, Germany. The original OTA circuit diagram shows two series combinations of a 5-kOmega resistor and a 20-pF capacitor connecting the outputs of the first stage to the inputs of the second stage, which is incorrect. The correct OTA schematic is shown in Fig. 1 below. The RC combinations are connected between the inputs and outputs of the second stage for Miller compensation with right-half-plane zero cancellation and the first and second stages are directly coupled. We apologize for this error.
Keywords
delta-sigma modulation; operational amplifiers; Miller compensation; OTA circuit diagram; capacitance 20 pF; continuous-time delta-sigma modulator; frequency 25 kHz; operational transconductance amplifier; resistance 5 kohm; return-to-open DAC; voltage 0.5 V; Capacitors; Delta modulation; Joining processes; Operational amplifiers; Phase noise; Resistors; Solid state circuits; Transconductance;