DocumentCode :
1226263
Title :
Design and experience with the BICOTH-type reactor water level gauge for the Dodewaard nuclear power plant
Author :
Ara, K. ; Katagiri, M. ; Termaat, K.P. ; Mostert, P. ; Johnston, T. ; Knudsen, K.
Author_Institution :
JAERI, Ibaraki, Japan
Volume :
36
Issue :
1
fYear :
1989
fDate :
2/1/1989 12:00:00 AM
Firstpage :
1251
Lastpage :
1255
Abstract :
An alternative system for measuring operating water levels in The Netherlands´ Dodewaard BWR (200 MWt, natural circulation) was developed. Its design is based on BICOTH (binary coding thermocouples with heater) sensors that contain heater wires and multijunction differential thermocouple wires. Binary codes are obtained that correspond uniquely to stable water levels present in a standpipe mounted to the inside of the reactor vessel wall. From the experiments, it was found that the additional use of the analog information contained in the temperature transition functions of the thermocouple junctions results in very accurate and smooth water-level indications. An advanced water-level sensor called TRICOTH (trinary coding thermocouples with heater) is proposed that is based on the design and operating experience with the present system
Keywords :
fission reactor cooling and heat recovery; fission reactor safety; nuclear power stations; BICOTH-type reactor water level gauge; BWR; Dodewaard nuclear power plant; TRICOTH; analog information; binary coding thermocouples with heater; design; heater wires; multijunction differential thermocouple wires; operating experience; temperature transition functions; trinary coding thermocouples with heater; Control systems; Inductors; Level control; Mechanical sensors; Power generation; Power measurement; Sensor systems; Thermal sensors; Water heating; Wires;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.34642
Filename :
34642
Link To Document :
بازگشت