Abstract :
If the high-potential part of a divider is of only about 1 pF, the divider can be made to respond at frequencies up to about 40 MHz. The capacitance of 1 pF can be made definite by suitable screening of the output terminal and everything connected to it.<>
Keywords :
high-voltage techniques; power overhead lines; transients; voltage dividers; voltage regulators; 1 pF; 40 MHz; HF; HV; overhead power lines; transients; voltage divider; voltage regulator;