• DocumentCode
    1226624
  • Title

    Determination of motor quality through routine electrical tests

  • Author

    Soukup, George C.

  • Author_Institution
    US Electr. Motors, St. Louis, MO, USA
  • Volume
    25
  • Issue
    5
  • fYear
    1989
  • Firstpage
    873
  • Lastpage
    880
  • Abstract
    Tests representing mechanical and electrical testing that can be performed on fully assembled motors are described. Associated benefits along with the corresponding costs are identified. The tests covered are heat run, performance locked-rotor, speed-torque, no-load-saturation, surge, high-potential, polarization-index, single-phase-rotor, Reed-critical-frequency, hot/cold vibration coastdown-critical, and bearing tests. General guidelines for test procedures are provided
  • Keywords
    electric motors; machine testing; Reed-critical-frequency; bearing tests; electrical tests; heat run; high potential tests; hot/cold vibration coastdown-critical; mechanical testing; motor quality; no-load-saturation; performance locked-rotor; polarization-index; single-phase-rotor; speed-torque tests; Acoustic testing; Costs; Frequency; Induction generators; Induction motors; Manufacturing; Performance evaluation; Petroleum; Temperature; Torque;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/28.41251
  • Filename
    41251