DocumentCode :
1226801
Title :
On Bayesian image reconstruction from projections: uniform and nonuniform a priori source information
Author :
Liang, Zhengrong ; Jaszczak, Ronald ; Greer, Kim
Author_Institution :
Dept. of Radiol., Duke Univ. Med. Center, Durham, NC, USA
Volume :
8
Issue :
3
fYear :
1989
fDate :
9/1/1989 12:00:00 AM
Firstpage :
227
Lastpage :
235
Abstract :
A method that incorporates a priori uniform or nonuniform source distribution probabilistic information and data fluctuations of a Poisson nature is presented. The source distributions are modeled in terms of a priori source probability density functions. Maximum a posteriori probability solutions, as determined by a system of equations, are given. Interactive Bayesian imaging algorithms for the solutions are derived using an expectation maximization technique. Comparisons of the a priori uniform and nonuniform Bayesian algorithms to the maximum-likelihood algorithm are carried out using computer-generated noise-free and Poisson randomized projections. Improvement in image reconstruction from projections with the Bayesian algorithm is demonstrated. Superior results are obtained using the a priori nonuniform source distribution
Keywords :
Bayes methods; computerised tomography; Bayesian image reconstruction from projections; Poisson type data fluctuations; computerised tomography; expectation maximization technique; interactive Bayesian imaging algorithms; maximum-likelihood algorithm; medical imaging; modelling; nonuniform a priori source information; uniform a priori source information; Bayesian methods; Image analysis; Image processing; Image recognition; Image reconstruction; Isotopes; Iterative algorithms; Maximum likelihood estimation; Poisson equations; Probability density function;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/42.34711
Filename :
34711
Link To Document :
بازگشت