• DocumentCode
    1227453
  • Title

    A newly modified forced oil cooling system and its impact on in-service transformer oil characteristics

  • Author

    Wahab, Mohamed Ahamed Abdel ; Hamada, Mohamed Mahmoud ; Zeitoun, Assad Gomah ; Ismail, Gamal

  • Author_Institution
    Dept. of Electr. Eng., Minia Univ., Egypt
  • Volume
    18
  • Issue
    3
  • fYear
    2003
  • fDate
    7/1/2003 12:00:00 AM
  • Firstpage
    827
  • Lastpage
    834
  • Abstract
    This paper introduces a newly modified forced oil-cooling system, which comprises a bypass filter (BPF). The BPF has been introduced in such a way that its intake oil is the hot oil from the transformer top and to deliver it at the inlet of the oil-circulating pump. This system has been used for two transformers. Periodical measurements of the physical, chemical, and electrical transformer oil characteristics by standard testing methods before BPF operation, in operation and after stopping its operation in the transformer have been carried out. Before BPF operation, the results revealed that these characteristics are continuously deteriorating with the increase in transformer oil service period. However, when BPF is in operation, this deterioration not only has been reduced but also some of the characteristics have been improved. After the operation of BPF has been stopped, some of the characteristics resumed their deterioration. However, the rates by which these characteristics are deteriorating are noticeably smaller than their initial values. The deteriorated transformer oil characteristics (without installation of BPF) have been predicted by polynomial regression, multiple linear regression, and general linear multiple regression models. The efficiency and feasibility of the new cooling system in preserving in-service transformer oil characteristics have been proved and justified by quantitative evaluation of the measured and theoretically predicted deteriorated (without installation of BPF) characteristics.
  • Keywords
    cooling; polynomials; power transformer insulation; statistical analysis; transformer oil; bypass filter; cooling system; deteriorated transformer oil characteristics; efficiency; general linear multiple regression models; hot oil; in-service transformer oil characteristics; intake oil; modified forced oil cooling system; multiple linear regression; oil-circulating pump; periodical measurements; polynomial regression; standard testing methods; transformer oil service period; transformer top; Band pass filters; Chemicals; Cooling; Electric variables measurement; Lubricating oils; Measurement standards; Oil insulation; Petroleum; Polynomials; Testing;
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/TPWRD.2003.813863
  • Filename
    1208363