DocumentCode :
1227761
Title :
Feeder Impedance of Variable-Speed and Constant-Frequency Generating Systems for Airplanes
Author :
Chen, Paul P.
Author_Institution :
The Boeing Company Seattle, Washington
Volume :
1
Issue :
2
fYear :
1963
Firstpage :
639
Lastpage :
646
Abstract :
The impedance of feeders used with variable-speed and constant-frequency (VSCF) generating systems in airplanes is severely affected by the non-sinusoidal generator current and the airplane frame. The above effect was experimentally investigated for frequencies from 1500 to 3500 cps. Data obtained are necessary for the analysis of system transient and steady-state behavior. Impedance curves were constructed as an aid in the determination of the optimum configuration and location of feeder cables for VSCF systems.
Keywords :
Aircraft; Airplanes; Cables; Circuit testing; Frequency conversion; Impedance measurement; Skin; Steady-state; Transient analysis; Voltage;
fLanguage :
English
Journal_Title :
Aerospace, IEEE Transactions on
Publisher :
ieee
ISSN :
0536-1516
Type :
jour
DOI :
10.1109/TA.1963.4319430
Filename :
4319430
Link To Document :
بازگشت