• DocumentCode
    1228664
  • Title

    A Micromachined Quartz Resonator Array for Biosensing Applications

  • Author

    Kao, Ping ; Doerner, Steffen ; Schneider, Thomas ; Allara, David ; Hauptmann, Peter ; Tadigadapa, Srinivas

  • Author_Institution
    Dept. of Electr. Eng., Pennsylvania State Univ., University Park, PA
  • Volume
    18
  • Issue
    3
  • fYear
    2009
  • fDate
    6/1/2009 12:00:00 AM
  • Firstpage
    522
  • Lastpage
    530
  • Abstract
    An 8-pixel micromachined quartz crystal resonator array with a fundamental resonance frequency of 66 MHz has been designed, fabricated, and tested. A compact impedance-spectrum-analyzer electronic interface has been developed and combined with the quartz resonator array to form the biosensing system. The sensor array was calibrated using water-glycerol solutions, and the performance was found to be exactly as expected. Measurement of the crosstalk between the sensor pixels showed an isolation of ~ 30 dB. Selective functionalization of the pixels was achieved through the use of aqueous 3, 3´-Dithiobis (sulfosuccinimidylpropionate) (DTSSP) molecules. The adsorption of avidin on DTSSP gave a frequency signal of 60 kHz in comparison to unfunctionalized pixels. The specific adsorption of avidin on functionalized pixels was confirmed through fluorescence microscopy. Comparing the performance of the micromachined quartz crystal microbalance (QCM) with a commercial 5-MHz device, we found that the micromachined QCM has a 4.25 times higher signal-to-noise ratio. Based on the measurement of the noise and using three times the frequency noise as the limit for the detection of avidin molecules, we expect to resolve a minimum of ~ 1/960 of a monolayer of avidin corresponding to an aerial mass density resolution of 0.7 ng/cm2.
  • Keywords
    adsorption; bioMEMS; biosensors; crystal resonators; fluorescence; microbalances; micromachining; micromechanical resonators; molecular biophysics; optical microscopy; proteins; spectral analysers; 3, 3´-Dithiobis (sulfosuccinimidylpropionate); DTSSP molecule; avidin adsorption; biosensing application; fluorescence microscopy; frequency 5 MHz; frequency 60 kHz; frequency 66 MHz; fundamental resonance frequency; impedance-spectrum-analyzer electronic interface; micromachined quartz crystal microbalance; micromachined quartz resonator array; noise measurement; water-glycerol solution; Biosensor array; impedance spectrum analyzer; quartz crystal microbalance (QCM); quartz micromachining;
  • fLanguage
    English
  • Journal_Title
    Microelectromechanical Systems, Journal of
  • Publisher
    ieee
  • ISSN
    1057-7157
  • Type

    jour

  • DOI
    10.1109/JMEMS.2009.2015498
  • Filename
    4812020