DocumentCode
1229382
Title
Adaptive Cancellation of Floor Vibrations in Standing Ballistocardiogram Measurements Using a Seismic Sensor as a Noise Reference
Author
Inan, Omer T. ; Etemadi, Mozziyar ; Widrow, Bernard ; Kovacs, Gregory T A
Author_Institution
Dept. of Electr. Eng., Stanford Univ., Stanford, CA, USA
Volume
57
Issue
3
fYear
2010
fDate
3/1/2010 12:00:00 AM
Firstpage
722
Lastpage
727
Abstract
An adaptive noise canceller was used to reduce the effect of floor vibrations on ballistocardiogram (BCG) measurements from a modified electronic bathroom scale. A seismic sensor was placed next to the scale on the floor and used as the noise reference input to the noise canceller. BCG recordings were acquired from a healthy subject while another person stomped around the scale, thus causing increased floor vibrations. The noise canceller substantially eliminated the artifacts in the BCG signal due to these vibrations without distorting the morphology of the measured BCG. Additionally, recordings were obtained from another subject standing inside a parked bus while the engine was running. The artifacts due to the vibrations of the engine, and the other vehicles moving on the road next to the bus, were also effectively eliminated by the noise canceller. The system with automatic floor vibration cancellation could be used to increase BCG measurement robustness in home monitoring applications. Additionally, the noise cancellation approach may enable BCG recording in ambulances-or other transport vehicles-where noninvasive hemodynamic monitoring may otherwise not be feasible.
Keywords
adaptive filters; biomechanics; biomedical measurement; cardiology; noise abatement; patient monitoring; road vehicles; vibration measurement; BCG; adaptive cancellation; adaptive noise canceller; ambulances; electronic bathroom scale; engine vibrations; floor vibrations; home monitoring applications; noise reference; noninvasive hemodynamic monitoring; seismic sensor; standing ballistocardiogram measurements; transport vehicles; Computerized monitoring; Distortion measurement; Engines; Morphology; Noise cancellation; Noise measurement; Noise robustness; Road vehicles; Seismic measurements; Vibration measurement; Adaptive noise cancellation; ballistocardiogram (BCG); cardiovascular disease; physiological monitoring; Adult; Algorithms; Artifacts; Ballistocardiography; Humans; Monitoring, Physiologic; Signal Processing, Computer-Assisted; Vibration;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/TBME.2009.2018831
Filename
4812084
Link To Document