• DocumentCode
    1229800
  • Title

    Measurement of Phase Angle Errors of Precision Current Shunts in the Frequency Range From 40 Hz to 200 kHz

  • Author

    Budovsky, Ilya

  • Author_Institution
    National Meas. Inst., Lindfield, NSW
  • Volume
    56
  • Issue
    2
  • fYear
    2007
  • fDate
    4/1/2007 12:00:00 AM
  • Firstpage
    284
  • Lastpage
    288
  • Abstract
    This paper describes the measurement techniques and results of the determination of phase angle errors of a set of National Measurement Institute, Australia, precision current shunts, rated from 100 mA to 20 A, in the frequency range from 40 Hz to 200 kHz. The standard uncertainties of the determination range from 1.3 murad at low frequencies to less than 150 murad at 200 kHz
  • Keywords
    measurement standards; measurement uncertainty; phase measurement; 0.040 to 200 kHz; 0.1 to 20 mA; Australia; National Measurement Institute; micropotentiometer; phase angle errors measurement; power measurement; precision current shunts; Australia; Broadband amplifiers; Current measurement; Frequency measurement; Goniometers; Phase measurement; Power measurement; Resistors; Testing; Wattmeters; Current shunt; micropotentiometer; phase angle error; power measurement;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2007.891117
  • Filename
    4126840