• DocumentCode
    1229830
  • Title

    A HOTLink/networked PC data acquisition and image reconstruction system for a high-resolution whole-body PET with respiratory or ECG-gated performance

  • Author

    Li, Hongdi ; Xing, Tao ; Liu, Yaqiang ; Wang, Yu ; Baghaei, Hossain ; Uribe, Jorge ; Ramirez, Rocio ; Wong, Wai-Hoi

  • Author_Institution
    Dept. of Exp. Diagnostic Imaging, Univ. of Texas M.D. Anderson Cancer Center, Houston, TX, USA
  • Volume
    50
  • Issue
    3
  • fYear
    2003
  • fDate
    6/1/2003 12:00:00 AM
  • Firstpage
    393
  • Lastpage
    397
  • Abstract
    An ultrahigh-resolution positron emission tomography (PET) camera in whole-body scanning or gated imaging study needs super computer-processing power for creating a huge sinogram as well as doing image reconstruction. A fast HOTLink serial bus attached to networked cluster personal computers (PC) has been developed for this special purpose. In general, the coincidence data from a PET camera is unidirectional; therefore, an additional daisy-chain bus using high-speed HOTLink (400 Mb/s, Cypress Semiconductor, inc.) transmitters and receivers is designed to carry the coincidence data to the entire networked (LAN) computers (PCs), the data from HOTLink are interfaced to a PC through a fast PCI I/O board (80 Mbyte/s). The overall architecture for the image acquisition and reconstruction computing system for a whole-body PET scanning is a pipeline design. One PC will acquire sinogram data for one bed position, and after completion of data acquisition that PC will begin to reconstruct the image. Meanwhile, another PC in the network will start data acquisition for the next bed position. The image results from the previous PC will be sent to a master computer for final tabulation and storage through the standard network, and then it will be free for processing a new bed position.
  • Keywords
    data acquisition; electrocardiography; image reconstruction; local area networks; medical image processing; microcomputer applications; pneumodynamics; positron emission tomography; system buses; ECG-gated performance; HOTLink/networked PC data acquisition; LAN; fast PCI I/O board; high-resolution whole-body PET; image reconstruction; image reconstruction system; networked cluster personal computers; respiratory performance; serial bus; ultrahigh-resolution positron emission tomography; whole-body scanning; Cameras; Computer networks; Data acquisition; High-resolution imaging; Image reconstruction; Image storage; Microcomputers; Positron emission tomography; Transmitters; Whole-body PET;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2003.812441
  • Filename
    1208601