DocumentCode :
1231719
Title :
A Thin Film Micro Thermocouple R.F. Energy Detector for Electro Explosive Device Wiring
Author :
Mulkey, Owen R.
Author_Institution :
The Boeing Company Aero-Space Division Seattle, Washington
Issue :
2
fYear :
1965
fDate :
6/1/1965 12:00:00 AM
Firstpage :
647
Lastpage :
651
Abstract :
A thin film thermocouple detector has been developed for use in the safety evaluation of electro explosive device wiring. The detector was fabricated using vacuum deposition techniques. Bismuth and tellurium were used as the thermoelectric materials. The resultant device has a thermoelectric power of 220 microvolts/??C and a response time of less than 17 milliseconds. Testing and calibration were accomplished using constant current pulse techniques.
Keywords :
Bismuth; Detectors; Explosives; Safety devices; Tellurium; Thermoelectricity; Thin film devices; Transistors; Vacuum technology; Wiring;