DocumentCode :
1232288
Title :
Cyclic and radial variation of the Doppler power from porcine whole blood
Author :
Paeng, Dong-Guk ; Shung, K. Kirk
Author_Institution :
Fac. of Marine Ind. Eng., Cheju Nat. Univ., Jeju, South Korea
Volume :
50
Issue :
6
fYear :
2003
fDate :
6/1/2003 12:00:00 AM
Firstpage :
614
Lastpage :
622
Abstract :
The Doppler power from porcine blood was observed in a mock flow loop to have cyclic and radial variation during a pulsatile cycle. It was found to decrease with shear rate under steady flow, except near the center of the tube at which other mechanisms such as the effects of radial distribution on the rouleaux might be involved. Under pulsatile flow, the timing of the peak of the Doppler power measured at the center of the tube became closer to the peak systole from 20 to 60 beats/minute (BPM), and the power and velocity peaks coincided at 60 BPM. The overall radial variation of the Doppler power during a whole pulsatile cycle was prominent due to the increase of shear rate from the center to 4.5 mm radial position within a tube of 6.35 mm radius. The cyclic variation of the Doppler power varied with the radial position, being relatively large at the center, reaching a minimum at an intermediate radial Position, and increasing again near the wall. The peak of the Doppler power occurred at early systole near the tube wall and lagged the flow closer to the center. The "black hole" phenomenon was observed only over portions of the flow cycle. All these complex variations of the Doppler power across the tube over a cycle are thought to be the result of red cell aggregation, which can be affected by shear rate and acceleration.
Keywords :
Doppler measurement; backscatter; biomedical ultrasonics; blood flow measurement; cellular biophysics; pulsatile flow; Doppler power; backscattered Doppler ultrasound; black hole phenomenon; cyclic variation; hemodynamic conditions; mechanisms; mock flow loop; porcine blood; porcine whole blood; pulsatile cycle; pulsed Doppler system; radial distribution; radial variation; red cell aggregation; rouleaux; shear rate; steady flow; tube wall; velocity peaks; whole pulsatile cycle; Acceleration; Backscatter; Blood; Frequency; Hemodynamics; Kirk field collapse effect; Performance analysis; Plasma measurements; Proteins; Rayleigh scattering; Acceleration; Animals; Blood; Blood Flow Velocity; Blood Physiology; Blood Pressure; Blood Vessels; Equipment Design; Erythrocyte Aggregation; Erythrocytes; Hemorheology; Motion; Periodicity; Pulsatile Flow; Scattering, Radiation; Sensitivity and Specificity; Shear Strength; Swine; Ultrasonography, Doppler, Pulsed;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2003.1209548
Filename :
1209548
Link To Document :
بازگشت