• DocumentCode
    1232318
  • Title

    Linear system models for ultrasonic imaging: application to signal statistics

  • Author

    Zemp, Roger J. ; Abbey, Craig K. ; Insana, Michael F.

  • Author_Institution
    Dept. of Biomed. Eng., California Univ., Davis, CA, USA
  • Volume
    50
  • Issue
    6
  • fYear
    2003
  • fDate
    6/1/2003 12:00:00 AM
  • Firstpage
    642
  • Lastpage
    654
  • Abstract
    Linear equations for modeling echo signals from shift-variant systems forming ultrasonic B-mode, Doppler, and strain images are analyzed and extended. The approach is based on a solution to the homogeneous wave equation for random inhomogeneous media. When the system is shift-variant, the spatial sensitivity function-defined as a spatial weighting function that determines the scattering volume for a fixed point of time-has advantages over the point-spread function traditionally used to analyze ultrasound systems. Spatial sensitivity functions are necessary for determining statistical moments in the context of rigorous image quality assessment, and they are time-reversed copies of point-spread functions for shift variant systems. A criterion is proposed to assess the validity of a local shift-invariance assumption. The analysis reveals realistic situations in which in-phase signals are correlated to the corresponding quadrature signals, which has strong implications for assessing lesion detectability. Also revealed is an opportunity to enhance near- and far-field spatial resolution by matched filtering unfocused beams. The analysis connects several well-known approaches to modeling ultrasonic echo signals.
  • Keywords
    biomedical ultrasonics; echo; image resolution; linear systems; medical image processing; sensitivity analysis; statistical analysis; ultrasonic imaging; US B-mode images; US Doppler images; US echo signal modeling; US imaging; US strain images; far-field spatial resolution; homogeneous wave equation; image quality assessment; in-phase signals; lesion detectability; linear system models; local shift-invariance; matched filtering unfocused beams; near-field spatial resolution; point-spread function; quadrature signals; random inhomogeneous media; scattering volume; shift-variant systems; signal statistics; spatial resolution enhancement; spatial sensitivity function; spatial weighting function; ultrasonic images; Capacitive sensors; Image analysis; Image quality; Linear systems; Nonhomogeneous media; Partial differential equations; Scattering; Signal analysis; Statistics; Ultrasonic imaging; Computer Simulation; Equipment Failure Analysis; Linear Models; Models, Biological; Quality Control; Reproducibility of Results; Scattering, Radiation; Sensitivity and Specificity; Ultrasonography;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2003.1209551
  • Filename
    1209551