• DocumentCode
    1233919
  • Title

    Fast Wafer Level Reliability Monitoring: Quantification of Plasma-Induced Damage Detected on Productive Hardware

  • Author

    Martin, Andreas ; Bukethal, Christoph ; Rydén, Karl-Henrik

  • Author_Institution
    Central Reliability Dept., Infineon Technol. AG, Munich
  • Volume
    9
  • Issue
    2
  • fYear
    2009
  • fDate
    6/1/2009 12:00:00 AM
  • Firstpage
    135
  • Lastpage
    144
  • Abstract
    This paper describes the investigation of a Plasma-Induced Damage (PID) event in the metal stack of an 8-in 130-nm-high volume process line. The relevant PID stress and measurement sequence used during standard productive fast Wafer Level Reliability Monitoring, which had detected this event, is discussed, and it is shown to be very effective. Additionally, hot carrier stress was performed on MOS transistors with antenna structures connected to the gate electrode for the quantification of the effect of PID on MOS device characteristics. It is demonstrated that the complete investigation can be done on production wafers in a very short time and only on scribe line test structures, saving time and hardware cost for extra wafers.
  • Keywords
    MOSFET; hot carriers; monitoring; reliability; MOS device characteristics; MOS transistors; PID stress; antenna structures; fast wafer level reliability monitoring; gate electrode; hardware cost; hot carrier stress; metal stack; plasma-induced damage; productive hardware; Antennas; process monitoring; reliability; semiconductor device testing; stress measurement;
  • fLanguage
    English
  • Journal_Title
    Device and Materials Reliability, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1530-4388
  • Type

    jour

  • DOI
    10.1109/TDMR.2009.2020601
  • Filename
    4813210