DocumentCode :
1234857
Title :
Distributions of measurement error for three-axis magnetic field meters during measurements near appliances
Author :
Misakian, Martin ; Fenimore, Charles
Author_Institution :
Nat. Inst. of Stand. & Technol., Gaithersburg, MD, USA
Volume :
45
Issue :
1
fYear :
1996
fDate :
2/1/1996 12:00:00 AM
Firstpage :
244
Lastpage :
249
Abstract :
Comparisons are made between the average magnetic flux density as would be measured with a three-axis coil probe and the flux density at the center of the probe. Probability distributions of the differences between the two quantities are calculated assuming a dipole magnetic field and are found to be asymmetric. The distributions allow estimates of uncertainty for resultant magnetic field measurements made near some electrical appliances and other electrical equipment
Keywords :
error analysis; magnetic field measurement; magnetometers; measurement errors; probability; asymmetric distributions; average magnetic flux density; dipole magnetic field; electrical appliances; electrical equipment; estimates of uncertainty; flux density; magnetic field measurements; measurement error; probability distributions; three-axis coil probe; three-axis magnetic field meters; Coils; Displays; Electrical products; Magnetic field measurement; Magnetic fields; Magnetic flux; Magnetic flux density; Measurement errors; Probes; Statistical distributions;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.481341
Filename :
481341
Link To Document :