DocumentCode :
1234990
Title :
Contactless and local measurement of temperature fluctuations at 60 GHz
Author :
Chenerie, I. ; Combes, P.F. ; Pouit, C.
Author_Institution :
Microwaves Dept., Univ. Paul Sabatier, France
Volume :
136
Issue :
4
fYear :
1989
fDate :
8/1/1989 12:00:00 AM
Firstpage :
358
Lastpage :
360
Abstract :
The study is aimed at reviewing the possibilities provided by millimetre waves for local and contactless measurement of temperature fluctuation Delta T. The authors propose to measure the noise temperature of oxygen molecules with a 60 GHz radiometer, allowing contactless measurement. The most original feature of the device is within the open resonator used as a sensor which allows local measurement. Moreover, for atmospheric measurements, the influence of water droplets can be easily taken into account by using microwave frequencies (see Rayleigh´s formulation for water droplet/wave interaction). The accuracy obtained on air temperature fluctuations is about 1 K (0, 5 K) for a response time of 0, 5 s (4 s) between 100 K and 400 K.
Keywords :
microwave measurement; radiometry; temperature measurement; 100 to 400 K; 60 GHz; MM waves; O2 molecules; air temperature; atmospheric measurements; contactless measurement; local measurement; noise temperature; open resonator; radiometer; temperature fluctuations; water droplets;
fLanguage :
English
Journal_Title :
Microwaves, Antennas and Propagation, IEE Proceedings H
Publisher :
iet
ISSN :
0950-107X
Type :
jour
Filename :
35472
Link To Document :
بازگشت