Title :
Producing 180° out-of-phase signals from a sinusoidal waveform input
Author :
Golnabi, Hossein ; Ashrafi, Ashkan
Author_Institution :
Inst. of Water & Energy, Sharif Univ. of Technol., Tehran, Iran
fDate :
2/1/1996 12:00:00 AM
Abstract :
In this paper a simple and novel method for producing two signals with 180° phase difference has been introduced. The phase-balanced signals are produced from a single sinusoidal input signal using two matched op-amps. The phase accuracy of the proposed circuit due to mismatched components is investigated with a two-pole model for the operational amplifiers. With high-precision integrated circuits, the phase error at the amplifier pole frequency a (2 MHz) is calculated to be about 0.5° which is a remarkable achievement. The discrete implementation of this scheme is also discussed, and there is a good agreement between the experimental results and the calculated values. The main features of this circuit make it suitable for use in bridge measuring systems and lock-in amplifiers
Keywords :
bridge circuits; bridge instruments; operational amplifiers; signal processing; signal processing equipment; waveform generators; 2 MHz; amplifier pole frequency; bridge measuring systems; integrated circuits; lock-in amplifiers; matched op-amps; mismatched components; operational amplifiers; out-of-phase signals; phase accuracy; phase error; phase-balanced signals; sinusoidal waveform input; two-pole model; Bridge circuits; Differential amplifiers; Frequency; Instruments; Inverters; Operational amplifiers; Performance evaluation; Resistors; Strain measurement; Transfer functions;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on