DocumentCode
1235161
Title
Transmission Properties of Filled Thermoplastic Insulated and Jacketed Telephone Cables at Voice and Carrier Frequencies
Author
Jachimowicz, L. ; Olszewski, J.A. ; Kolodny, I.
Author_Institution
General Cable Corporation, Union, NJ, USA
Volume
21
Issue
3
fYear
1973
fDate
3/1/1973 12:00:00 AM
Firstpage
203
Lastpage
209
Abstract
Interest is increasing in thermoplastic insulated and jacketed cables that are filled to minimize the entry and flow of water within the core. Such cable designs provide reliable, stable transmission characteristics, particularly for the increasingly popular pulse-code modulation (PCM) systems. This paper explores the primary and secondary electrical parameters of filled telephone cables in the voice and carrier frequency range. In addition, data are presented on nearend and far-end crosstalk.
Keywords
Crosstalk; Telephone cables; Thermoplastic-insulated cables; Cable insulation; Capacitance; Circuit testing; Communication cables; Crosstalk; Frequency; Impedance; Pulse modulation; Telephony; Temperature measurement;
fLanguage
English
Journal_Title
Communications, IEEE Transactions on
Publisher
ieee
ISSN
0090-6778
Type
jour
DOI
10.1109/TCOM.1973.1091645
Filename
1091645
Link To Document