• DocumentCode
    1235161
  • Title

    Transmission Properties of Filled Thermoplastic Insulated and Jacketed Telephone Cables at Voice and Carrier Frequencies

  • Author

    Jachimowicz, L. ; Olszewski, J.A. ; Kolodny, I.

  • Author_Institution
    General Cable Corporation, Union, NJ, USA
  • Volume
    21
  • Issue
    3
  • fYear
    1973
  • fDate
    3/1/1973 12:00:00 AM
  • Firstpage
    203
  • Lastpage
    209
  • Abstract
    Interest is increasing in thermoplastic insulated and jacketed cables that are filled to minimize the entry and flow of water within the core. Such cable designs provide reliable, stable transmission characteristics, particularly for the increasingly popular pulse-code modulation (PCM) systems. This paper explores the primary and secondary electrical parameters of filled telephone cables in the voice and carrier frequency range. In addition, data are presented on nearend and far-end crosstalk.
  • Keywords
    Crosstalk; Telephone cables; Thermoplastic-insulated cables; Cable insulation; Capacitance; Circuit testing; Communication cables; Crosstalk; Frequency; Impedance; Pulse modulation; Telephony; Temperature measurement;
  • fLanguage
    English
  • Journal_Title
    Communications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0090-6778
  • Type

    jour

  • DOI
    10.1109/TCOM.1973.1091645
  • Filename