• DocumentCode
    1238500
  • Title

    Superconducting current transformer for testing Nb3Sn cable splicing technique

  • Author

    Andreev, N. ; Barzi, E. ; Bhashyam, S. ; Boffo, C. ; Chichili, D.R. ; Yadav, S. ; Terechkine, I. ; Zlobin, A.V.

  • Author_Institution
    Fermilab, Tech. Div., Batavia, IL, USA
  • Volume
    13
  • Issue
    2
  • fYear
    2003
  • fDate
    6/1/2003 12:00:00 AM
  • Firstpage
    1274
  • Lastpage
    1277
  • Abstract
    To provide a quick feedback on different approaches to superconducting cable splicing design and assembly techniques, a superconducting current transformer that can deliver more than 20 kA for testing splice samples was designed and fabricated. The existing infrastructure of the Short Sample Test Facility at Fermilab, including its cryostat, power supply, and data acquisition system, was used for housing and operating the transformer. This report presents the design features of the transformer and the main results of cable splice tests.
  • Keywords
    cable jointing; current transformers; niobium compounds; superconducting cables; superconducting transformers; 20 kA; Nb3Sn; Short Sample Test Facility; assembly techniques; cable splicing technique; cryostat; data acquisition system; housing; splice tests; superconducting cable; superconducting current transformer; Assembly; Current transformers; Data acquisition; Feedback; Niobium; Power supplies; Splicing; Superconducting cables; Test facilities; Testing;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/TASC.2003.812644
  • Filename
    1211830