• DocumentCode
    1240745
  • Title

    A sophisticated maximum capacity analysis for large turbine generators considering limitation of temperature

  • Author

    Ide, Kazumasa ; Hattori, Ken Ichi ; Takahashi, Kazuhiko ; Kobashi, Keiji ; Watanabe, Takashi

  • Author_Institution
    Hitachi Res. Lab., Hitachi Ltd., Ibaraki, Japan
  • Volume
    20
  • Issue
    1
  • fYear
    2005
  • fDate
    3/1/2005 12:00:00 AM
  • Firstpage
    166
  • Lastpage
    172
  • Abstract
    In this paper, the authors propose a sophisticated analysis method to determine possible maximum generator capacity and to evaluate the generator´s potential ability. The method surveys generator design parameters on a large scale efficiently and objectively. The possible maximum generator capacity acquired by the proposed method satisfies the specifications of short-circuit ratio, power factor, and temperature limitations of armature and field windings. Armature voltage, armature current, and field current are adjusted to satisfy the above specifications simultaneously. An example adopting the proposed method is shown which clarifies the method´s effectiveness in the research and design phase. The specific results obtained demonstrate the sensitivities of the calculated possible maximum generator capacity and the calculated loss for various development factors.
  • Keywords
    machine windings; power factor; turbogenerators; air-cooled turbine generator; armature winding; field winding; generator design parameter; large turbine generator; power factor; short-circuit ration; sophisticated maximum capacity analysis; temperature limitation; Design methodology; Laboratories; Large-scale systems; Magnetic analysis; Power generation; Reactive power; Stators; Temperature distribution; Turbines; Ventilation;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/TEC.2004.842389
  • Filename
    1396096