DocumentCode :
1241057
Title :
T2 restoration and noise suppression of hybrid MR images using Wiener and linear prediction techniques
Author :
Chen, Haiguang ; Avram, Hector ; Kaufman, Leon ; Hale, James ; Kramer, David
Author_Institution :
Radiol. Imaging Lab., California Univ., San Francisco, CA, USA
Volume :
13
Issue :
4
fYear :
1994
fDate :
12/1/1994 12:00:00 AM
Firstpage :
667
Lastpage :
676
Abstract :
The authors address the problem of enhancing hybrid magnetic resonance (MR) images degraded by T2 effects and additive measurement noise. To reduce imaging time, MR signals are acquired using hybrid imaging (HI) sequences such as rapid acquisition relaxation-enhanced (RARE) and fast spin-echo (FSE). With these techniques, T2 effects act as a distortion filter. This T2 filter affects the signal and results in image spatial resolution and/or contrast loss. Furthermore, the amplitude and phase discontinuities in the T2 filter frequency response function may generate serious ringing artifacts. These distortions will damage image quality and affect object detectability. The authors use the Wiener filter and linear prediction (LP) technique to process HI MR signals in the spatial frequency domain (K-space) and the hybrid domain, respectively. Based on the average amplitude symmetry constraint of the spin echo signal, the amplitude frequency response function of the T2 distortion filter can be estimated and used in the Wiener filter for a global T2 amplitude restoration. Then, the linear prediction technique is utilized to obtain the local signal amplitude and phase estimates around the discontinuities of the frequency response function of the T2 filter. These estimates are used to make local amplitude and phase corrections. The effectiveness of this combined technique in correcting T2 distortion and reducing the measurement noise is analyzed and demonstrated using experiments on both phantoms and human studies
Keywords :
biomedical NMR; image enhancement; medical image processing; spin-spin relaxation; T2 distortion correction; T2 restoration; contrast loss; hybrid MR images; hybrid magnetic resonance images enhancement; image spatial resolution; magnetic resonance imaging; measurement noise; medical diagnostic imaging; noise suppression; ringing artifacts; spin echo signal; Additive noise; Amplitude estimation; Distortion measurement; Frequency response; Image restoration; Magnetic noise; Magnetic resonance imaging; Noise measurement; Signal restoration; Wiener filter;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/42.363101
Filename :
363101
Link To Document :
بازگشت