• DocumentCode
    1242700
  • Title

    An observer study methodology for evaluating detection of motion abnormalities in gated myocardial perfusion SPECT

  • Author

    Lalush, David S. ; Jatko, Megan K. ; Segars, W. Paul

  • Author_Institution
    Dept. of Biomed. Eng., Univ. of North Carolina, Chapel Hill, NC, USA
  • Volume
    52
  • Issue
    3
  • fYear
    2005
  • fDate
    3/1/2005 12:00:00 AM
  • Firstpage
    480
  • Lastpage
    485
  • Abstract
    To address the task of detecting nonischemic motion abnormalities from animated displays of gated myocardial perfusion single photon emission computed tomography data, we performed an observer study to evaluate the difference in detection performance between gating to 8 and 16 frames. Images were created from the NCAT mathematical phantom with a realistic heart simulating hypokinetic motion in the left lateral wall. Realistic noise-free projection data were simulated for both normal and defective hearts to obtain 16 frames for the cardiac cycle. Poisson noise was then simulated for each frame to create 50 realizations of each heart. All datasets were processed in two ways: reconstructed as a 16-frame set, and collapsed to 8 frames and reconstructed. Ten observers viewed the cardiac images animated with a realistic real-time frame rate. Observers trained on 100 images and tested on 100 images, rating their confidence on the presence of a motion defect on a continuous scale. None of the observers showed a significant difference in performance between the two gating methods. The 95% confidence interval on the difference in areas under the ROC curve (Az8-Az16) was -0.029-0.085. Our test did not find a significant difference in detection performance between 8-frame gating and 16-frame gating. We conclude that, for the task of detecting abnormal motion, increasing the number of gated frames from 8 to 16 offers no apparent advantage.
  • Keywords
    cardiology; haemorheology; image motion analysis; image reconstruction; medical image processing; phantoms; single photon emission computed tomography; NCAT mathematical phantom; Poisson noise; gated myocardial perfusion SPECT; image reconstruction; left lateral wall; nonischemic motion abnormalities detection; observer study; realistic heart simulating hypokinetic motion; realistic noise-free projection data; single photon emission computed tomography; Animation; Computational modeling; Displays; Heart; Image reconstruction; Motion detection; Myocardium; Performance evaluation; Single photon emission computed tomography; Testing; Gated SPECT; myocardial SPECT; Artificial Intelligence; Gated Blood-Pool Imaging; Heart Ventricles; Humans; Image Interpretation, Computer-Assisted; Movement; Observer Variation; Phantoms, Imaging; Reproducibility of Results; Sample Size; Sensitivity and Specificity; Task Performance and Analysis; Tomography, Emission-Computed, Single-Photon; Ventricular Dysfunction, Left; Video Recording;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2004.843290
  • Filename
    1396388